TT518PD(32/280)F1Z
 |
Click to enlarge image(s)
|
Call us for updated pricing.
Overview
This transmitter amplifies a signal from a RTD or linear resistance, and it turns the signal into a current which increases from 4 to 20 milliamperes as the temperature or input signal increases. This industry-standard 4-20mA signal travels thousands of feet over a pair of wires, ignoring electrical interference and bringing the temperature, accurately, into your computer or controller. Drawing power directly from the signal line, only 2 wires are needed for power and signal.
- RTD or Ohm input
- Accurate, Stable 4–20mA Output
- PC and field-programmable
- FM Approved Intrinsically Safe
Converts multiple inputs
Temperature measurement can be done with one of several RTD’s: 100 Ω, 1000 Ω platinum, 100 Ω Nickel and 1000 Ω Nickel. Because amplification and conversion of the input signal is performed within a few feet of the sensor, electrical interference in noisy environments is eliminated. The transmitter can be mounted at the field location in a standard DIN form B head or on a DIN rail inside a local box.
Supply Voltage
|
8-30 VDC
|
Warm-Up Time
|
5 min.
|
Communication Interface
|
PC Interface/Loop Link
|
Signal/noise ratio
|
Min. 60 dB
|
Response Time (programmable)
|
0.33 sec. to 60 sec.
|
Update Time
|
135 msec
|
Calibration Temperature
|
20 to 28°C
|
Effect of supply voltage change
|
< 0.005% of span/ VDC
|
EMC-lmmunity influence
|
< ±0.5% of span
|
Vibration
|
IEC 600 68-2-6 Test FC
|
Lloyd's specification no. 1
|
4 g / 2 - 100 Hz
|
Max. wire size
|
AWG14
|
Air Humidity
|
0-95% RH
|
Dimensions
|
∅1.73 x 0.84 in (∅44 x 20.2mm)
|
Tightness (enclosure/terminal)
|
IP 68 / IP00
|
TT518
|
Model Number: TT518 Temperature Transmitter
|
PD = Sensor Type
|
100 Ω Platinum RTD (0.00385)
|
Ranging
|
32 - 280°F
|
F = Display Units
|
Farenheit
|
1 = Calibration
|
Nominal
|
Z = Sensor Leads
|
3-lead RTD
|