CSM30904-000
|
|
Click to enlarge image(s)
|
PLEASE CALL FOR DELIVERY. STANDARDD DELIVERY DOES NOT APPLY
HOTSTART’s HOTflowTM heating system (CTM model) is a complete coolant preheater with thermostat, pump and all required controls. The CSM model heats engines ranging in size from 15L-100L displacement. Forced circulation of the coolant delivers uniform heating throughout the entire engine, extends element life and offers a significant reduction in electrical consumption.
APPLICATION
HOTflowTM model CSM was developed to preheat diesel and gas engines for stationary land power, marine, large mining and construction equipment.
Watts |
9000 |
Amps |
20.8 |
Phase |
Three |
Voltage |
480 V |
Frequency |
60 Hz |
Engine Size |
3000-4500 CID - 50-75 Liters |
- Heating Fluid: Engine coolant (50% glycol/50% water)
- Tank Material: Aluminum
- Adjustable T-Stat: 90° - 130°F (32°- 55°C)
Pre-set at 110°F (43.5°C)
- Ingress Protection: IP44 (50Hz), NEMA 2 (60Hz)
- Fluid Capacity: 0.6gl (2.19L)
- Flow: 10GPM (2.2 m3/hr) @ 10ft head (0.3bar)
- Max PRessure: 125 PSI (8.61bar)
- Pressure Loss: 0.22PSI (0.015bar)
- 1" NPT Inlet, 1" NPT Outlet
UL-C/US listed - (60 Hz models) - E250789CE
|
|
Compact design
|
|
Easy to install
|
|
Controls for automatic operation
|
|